Vaisala DRYCAP DMT345 Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Vaisala DRYCAP DMT345. CEN Global DMT345 DMT346 Datasheet B210723EN-D Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
www.vaisala.com
DMT345 and DMT346 Dewpoint Transmitters
for High Temperature Applications
The Vaisala DRYCAP
®
Dewpoint
Transmitters DMT345 and
DMT346 are designed for humidity
measurement in industrial drying
applications with particularly high
temperatures.
Both transmitters incorporate the
Vaisala DRYCAP
®
sensor, which is
accurate, reliable, and stable. The
sensor withstands condensation
and is immune to particulate
contamination, oil vapor and most
chemicals. The DRYCAP
®
sensor
stands out for its swift response time
and rapid recovery after getting wet.
Measure Humidity Directly
in Hot Processes
The DMT345 and DMT346 are
constructed for direct measurement
in hot processes. Therefore, there
is no need for sampling systems
and trace heating. As a result,
high accuracy and constancy are
maintained.
The Vaisala DRYCAP
®
Dewpoint Transmitters DMT345 and DMT346 are designed
to measure and control humidity especially in dry environments with high
temperatures.
The accuracy and stability of the
DMT345 and the DMT346 are due to
the unique auto-calibration function,
patented by Vaisala. This auto-
calibration makes the transmitter
perform a calibration and adjustment
by itself while the measured process
is running. If the measurement
accuracy is not conrmed, corrections
are made automatically. The
procedure is so quick and corrections
are so minor that it will go unnoticed.
This ensures low maintenance
and high performance. In normal
conditions, it is recommended to have
a traceable calibration performed
once a year.
DMT345, Accurate in Hot
and Dry Environments
The DMT345 is designed for accurate
humidity measurement in hot and
dry conditions. This model provides
unmatched dry end measurement
accuracy in temperatures up to 140 °C,
however the DMT345 can operate
safely in temperatures up to 180 °C.
The stainless steel probe is especially
designed for high temperatures and
has an optional installation ange that
allows an adjustable installation depth
and therefore a precise positioning.
Features/Benefits
The DMT345 measures
humidity in temperatures up to
180 °C (356 °F)
The DMT346 measures
humidity in temperatures up to
350 °C (+662 °F)
Dew point accuracy ±2 °C
3.6 °F)
Vaisala DRYCAP® Sensor
provides accurate, reliable
measurement with excellent
long-term stability and fast
response
Withstands condensation
Unique auto-calibration feature
Optional local display with
keypad, mains power supply
module and alarm relays
NIST traceable calibration
(certificate included)
Analog outputs, WLAN/LAN
MODBUS protocol support
(RTU/TCP)
The large and clear display allows the
user to check data at a glance.
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - DMT345, Accurate in Hot

www.vaisala.comDMT345 and DMT346 Dewpoint Transmitters for High Temperature ApplicationsThe Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 ar

Pagina 2 - Technical Data

Technical DataMeasured Variables DMT345DEWPOINT DMT345Sensor Vaisala DRYCAP®180SMeasurement range -40 ... +100 °C (-40 ... +212 °F) TdAccuracy ±2°C (±

Pagina 3

Technical DataOperating Environment, Both ModelsMechanical durability Up to +180 °C (+356 °F) for DMT345of probes Up to +350 °C (+662 °F) for DMT346fo

Pagina 4 - Dimensions

Technical DataDimensionsDimensions in mm (inches)DMT345 and DMT346 Transmitter housingDRYCAP® is a registered trademark of Vaisala.Ref. B210723EN-D ©V

Comentarios a estos manuales

Sin comentarios