USER'S GUIDE
Vaisala HUMICAP® Hand-Held
Moisture and Temperature in Oil Mete
r
MM70
M210878EN-A
North America
Vista de pagina 0
1 2 3 4 5 6 ... 66 67

Indice de contenidos

Pagina 1 - USER'S GUIDE

USER'S GUIDE Vaisala HUMICAP® Hand-Held Moisture and Temperature in Oil MeterMM70 M210878EN-ANorth America

Pagina 2

USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 8 _____________

Pagina 3 - Table of Contents

Chapter 2 _____________________________________ PRODUCT OVERVIEW AND MECHANICS CHAPTER 2 PRODUCT OVERVIEW AND MECHANICS Vaisala´s Hand-held MM70 Devi

Pagina 4 - CHAPTER 5

USER'S GUIDE____________________________________________________________________ Structure of the MI70 Indicator 0605-094 Figure 1 MI Indic

Pagina 5 - List of Figures

Chapter 2 _____________________________________ PRODUCT OVERVIEW AND MECHANICS Structure of the MMP78 Probe 0605-087 Figure 2 MMP78 Probe The follo

Pagina 6 - List of Tables

USER'S GUIDE____________________________________________________________________ Display Parameters - aw: water activity - T: temperature (°C/

Pagina 7 - GENERAL INFORMATION

Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS CHAPTER 3 INSTALLATION AND MOUNTING OPTIONS Installing and Rechargin

Pagina 8 - License Agreement

USER'S GUIDE____________________________________________________________________ 2. Press the power on/off key. 3. Select the language by usi

Pagina 9 - Warranty

Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS measurements in pipelines. The maximum installation pressure is 10 ba

Pagina 10

USER'S GUIDE____________________________________________________________________ 0605-080 Figure 5 Tightening Clasp Nut The following numbers

Pagina 11 - MECHANICS

Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS 0605-083 Figure 6 Sealing Thread Cutting for the Fitting Body CAUT

Pagina 12 - 0605-094

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at ht

Pagina 13

USER'S GUIDE____________________________________________________________________ 3. Make sure that the temperature at the measurement point is

Pagina 14 - Options

Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS NOTE The probe can be installed in the process through the ball valve

Pagina 15 - OPTIONS

USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 20 ____________

Pagina 16 - Installing the Probe

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS CHAPTER 4 MENU OPERATIONS AND SETTINGS Function Keys and Menu Structu

Pagina 17 - Tightening the Clasp Nut

USER'S GUIDE____________________________________________________________________ - To turn the indicator on or off, press the power On/Off key.

Pagina 18 - 0605-080

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Function keys are shortcuts to some functions or menus. Shortcuts fo

Pagina 19

USER'S GUIDE____________________________________________________________________ Settings Display Settings 0605-102 Figure 11 Display Sett

Pagina 20 - 0605-085

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 1. Open the MENU. First press the right arrow key, and then press the

Pagina 21

USER'S GUIDE____________________________________________________________________ 1. Open the MENU. First press the right arrow key, and then pre

Pagina 22

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Selecting Language You can select any of the following languages for

Pagina 23 - MENU OPERATIONS AND SETTINGS

________________________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION...

Pagina 24 - Basic Display

USER'S GUIDE____________________________________________________________________ Changing the Shorcut Keys As a default, the function keys are s

Pagina 25 - Main Menu

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 3. Select Date and Time. Press the right arrow key. 4. To change th

Pagina 26 - Rounding

USER'S GUIDE____________________________________________________________________ 0605-099 Figure 14 Device Information Submenus Restoring Fac

Pagina 27 - Graphic History

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS MM70 alarms by beeping and blinking the backlight. The alarm turns on

Pagina 28 - User Interface Settings

USER'S GUIDE____________________________________________________________________ Selecting and Scaling the Analog Output 0605-093 Figure 16 A

Pagina 29 - Automatic Power Off

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 7. Select 0.0 V to set the value for the 0.0 V output signal, press t

Pagina 30 - Setting Date and Time

USER'S GUIDE____________________________________________________________________ 2. Connect the DMP70/GMP70/HMP70 probe to the other connector p

Pagina 31 - Device Information

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 8. Start recording: Select Start/Stop recording, press the START key.

Pagina 32 - Setting the Alarm Levels

USER'S GUIDE____________________________________________________________________ Viewing Recorded Data 1. Open the MENU. First press the right a

Pagina 33

Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Transferring Recorded Data to PC The recorded data can be transferred

Pagina 34 - 0605-093

USER'S GUIDE____________________________________________________________________ Rounding ...

Pagina 35

USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 38 ____________

Pagina 36 - Recording

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT CHAPTER 5 CALIBRATION AND ADJUSTMENT General Notes about Calibration

Pagina 37 - Stopping Recording

USER'S GUIDE____________________________________________________________________ Calibration and Adjustment of HMP228 Series Transmitters You ca

Pagina 38 - Deleting All Recorded Files

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 0605-091 Figure 18 Adjustment Mode Relative Humidity Adjustment by

Pagina 39

USER'S GUIDE____________________________________________________________________ 4. Wait until the reading is stabilized (takes about 30 minute

Pagina 40

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 10. Enter the second reference humidity value by using the arrow key

Pagina 41 - CALIBRATION AND ADJUSTMENT

USER'S GUIDE____________________________________________________________________ 1. Select aw, RH, T or H2O (H2O can only be checked, not adjust

Pagina 42 - HMP228 Series Transmitters

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 8. Adjustment is done. To return to the basic display, first press t

Pagina 43 - 1-point Relative Humidity

USER'S GUIDE____________________________________________________________________ Calibration and Adjustment of MMT330 Transmitters You can check

Pagina 44 - 2-point Relative Humidity

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 2. Check that the probes are located in equal conditions and wait un

Pagina 45 - MMT318 Transmitters

________________________________________________________________________________ 2-point Adjustment ...

Pagina 46 - Calibrator

USER'S GUIDE____________________________________________________________________ 2-point Adjustment by Using a Calibrator When using this adjust

Pagina 47

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT Calibration and Adjustment of MM70 Series Probes General about Calib

Pagina 48 - MMT330 Transmitters

USER'S GUIDE____________________________________________________________________ have to feed the reference values, the MM70 displays the accura

Pagina 49

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 14. Confirm the adjustment, press the YES key (by pressing the NO ke

Pagina 50

USER'S GUIDE____________________________________________________________________ 1-point Adjustment When using this adjustment method, start wit

Pagina 51

Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 8. Calibration is done. To return to the basic display, first press

Pagina 52 - 2-point Adjustment

USER'S GUIDE____________________________________________________________________ 54 ___________________________________________________________

Pagina 53 - Temperature Adjustment

Chapter 6 ___________________________________________________________ MAINTENANCE CHAPTER 6 MAINTENANCE Changing the Filter and Sensor 1. Screw out t

Pagina 54

USER'S GUIDE____________________________________________________________________ Changing the Battery A new rechargeable battery pack can be or

Pagina 55 - Error Message Types

Chapter 6 ___________________________________________________________ MAINTENANCE Vaisala Service Centers VAISALA __________________________________

Pagina 56

USER'S GUIDE____________________________________________________________________ Figure 19 Installing the Battery Pack...

Pagina 57 - MAINTENANCE

USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 58 _____________

Pagina 58 - Changing the Battery

Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS CHAPTER 7 TECHNICAL SPECIFICATIONS Measured Variables Water Activity

Pagina 59 - Vaisala Service Centers

USER'S GUIDE____________________________________________________________________ MMP78 Probe Humidity sensor HUMICAP Temperature sensor Pt 100

Pagina 60

Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS Accuracy 0.2 % full scale Temperature dependence 0.002 %/ C full s

Pagina 61 - TECHNICAL SPECIFICATIONS

USER'S GUIDE____________________________________________________________________ Options and Accessories Available Table 2 List of Options and

Pagina 62 - MI70 Indicator

Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS Dimensions in mm (inches) Figure 20 MI70 Indicator VAISALA _

Pagina 63 - Temperature Meter

USER'S GUIDE____________________________________________________________________ 64 ____________________________________________________________

Pagina 64

www.vaisala.com *M210878EN*

Pagina 65 - Dimensions in mm (inches)

Chapter 1 __________________________________________________ GENERAL INFORMATION CHAPTER 1 GENERAL INFORMATION About This Manual This manual provides

Pagina 66 - 170 (6.69)

USER'S GUIDE____________________________________________________________________ To make sure you are not delivering high static voltages yourse

Pagina 67

Chapter 1 __________________________________________________ GENERAL INFORMATION Warranty Vaisala hereby represents and warrants all Products manufact

Comentarios a estos manuales

Sin comentarios