Chapter 6 ____________________________________________________ Configuration commands
VAISALA _______________________________________________________________________ 77
NOTE
There is a 100-millisecond delay after which WMT700 takes the settings
into use. Do not send commands to WMT700 during this time.
BAUD x,y,z,w
where
x = Bit rate (300, 1200, 2400, 4800, 9600, 19200, 38400,
57600, or 115200)
y = Data bits (7 or 8)
z = Parity (n = none, e = even, o = odd)
w = Stop bits (1 or 2)
Example:
In this example the bit rate is set to 115200, data bits to 8, parity to none,
and stop bits to 1.
BAUD 115200,8,n,1
Display Port Settings
You can use the BAUD command to display the current serial port
settings.
BAUD
Wind Measurement Control Commands
MEAS — Single Wind Measurement
This command starts wind measurement based on the user-configurable
averaging time. WMT700 does not send the data message automatically.
Use the polling command to fetch measurement data in the required data
message format.
MEAS