HMD60U/Y Transmitters
Operating Manual U301en-1.1
10 1997-07-31
6.3 General
Supply voltage 10...35 VDC (R
L
= 0)
20...35 VDC (R
L
=500)
Output signal 4...20 mA
Operating temperature range:
electronics -5...+55 °C
sensor head -40...+80 °C
Storage temperature range -40...+80 °C
Housing:
sensor head stainless steel
electronics housing cast aluminium
Cable lead-through:
bushing for 7...10 mm (PG9) cable
(housing IP65 / NEMA 4),
part no. 18941HM
or armoured cable glands part no. 10528HM
Sensor protection:
standard membrane filter
(part no. 17039HM)
option stainless steel sintered filter
(part no. HM46670)
Connections screw terminals 0.5...1.5 mm
2