Chapter 5 ________________________________________ Advanced Use of Lizard Setup Software
VAISALA______________________________________________________________________ 211
0711-129
Figure 110 Reports View: Binary Report Formatting Frame
(2/2)
- Bit count indicates how many bits are included in this report.
- Byte count indicates how many bytes are included in this report.
- Zero, return number zero. This parameter can be used to add a
constant into the binary report. Offset and multiplier are used to set
a constant using the following formula:
constant = (Zero + Offset) × Multiplier(=1)