Chapter 5 _____________________________________________________________ Technical Data
VAISALA________________________________________________________________________ 19
CHAPTER 5
TECHNICAL DATA
Technical Specifications
Operating Range
Pressure range (order specified) 500 ... 1100 hPa
800 ... 1060 hPa
600 ... 1060 hPa
900 ... 1100 hPa
Operating temperature range -40 ... +60°C
Humidity range non condensing
Accuracy
Non linearity* ± 0.20 hPa
Hysteresis* ± 0.05 hPa
Repeatability* ± 0.05 hPa
Calibration uncertainty** ± 0.15 hPa
Total accuracy (20°C)*** ± 0.30 hPa
Temperature dependence
(-40 ... +60°C)**** ± 0.50 hPa
Total accuracy***
(-40 ... +60°C) ± 0.60 hPa