Vaisala WINDCAP WS425 Guía de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 91
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
Chapter 2 __________________________________________________________ Product Overview
VAISALA_______________________________________________________________________ 21
0506-014
Figure 6 Cable Assembly, Sensor
The sensor interface cable assembly is 11.2 m in length. The 12 ring
lugs (indicated by the arrow in Figure 6 on page 21) of the sensor
interface cable are each numbered 1-12. Connect them to the
correspondingly numbered terminal positions in the power supply
assembly terminal block 2; see Figure 5 on page 20, Figure 11 on page
30 and Table 2 on page 31.
Accessories
Ultrasonic Wind Sensor WS425 F/G also has the following optional
accessories:
- Fiber optic modem, FOM111
0506-055
Figure 7 Fiber Optic Modem FOM111
The following numbers refer to Figure 7 on page 21:
1 = Fiber optic connectors
2 = RS-232 connector for PC cable
3 = Screw wire terminals for operating voltage