4Humidity/ TECHNOLOGY DESCRIPTIONVaisala HUMICAP® Sensor for Measuring Relative HumidityIn 1973, Vaisala introduced HUMICAP®, the world’s first thin-fil
13Vaisala Humidity Calibrator HMK15 for multi-point on-site calibrations.Humidity Instrument CalibrationIn calibration, the humidity reading of an ins
www.vaisala.com14HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity MeasurementThe Vaisala HUMICAP® Humidity and Temperature T
15HumidityWide Range of Installation Options The wide variety of measurement probes, several installation accessories, and universal mains and DC powe
16Technical Data °C°C00-80 -60 -40 -20 20 40 60 80 100 120 140 160180-0.7-0.6-0.5-0.4-0.3-0.2-0.10.10.20.30.40.50.60.7Temperature sensor Pt100 RTD Cla
17Ref. B210951EN-E ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners.
18HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted ApplicationsThe Vaisala HUMICAP® Humidity and Temperature Transmitter HMT331
19The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT334 is designed for humidity measurement in pressurized spaces or vacuum chambers. Ever
20The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT337 is delivered in one of three configurations:• Basic,withanon-warmedprobeform
21HumidityThe Vaisala HUMICAP® Humidity and Temperature Transmitter HMT338 is designed for pressurized processes.Insert or Remove the Probe while the
22HMT331 probe37.5 (1.48)78.5 (3.09)98.5 (3.88)Ø 12 (0.47)M9x1HMT333 probeM22×1.5 orNPT 1/2"120 (4.72)170 (6.69)41 (1.61)ø12 (0.47)HMT334 pro
5For more information, visitwww.vaisala.com or contact us at [email protected]. B210781EN-C ©Vaisala 2012This material is subject to copyright prot
23Humiditywww.vaisala.com/[email protected] quality and profitability of your process equals the quality of your measurement.The success of
www.vaisala.com24HMT360 Series Intrinsically Safe Humidity and Temperature TransmittersThe Vaisala HUMICAP® Humidity and Temperature Transmitter Serie
25Interchangeable Probes for HMT360 Intrinsically Safe Humidity and Temperature TransmitterDimensionsDimensions in mm (inches) DimensionsDimensions i
26DimensionsDimensions in mm (inches) DimensionsDimensions in mm (inches) DimensionsDimensions in mm (inches) Technical DataHMP365 for high temperatur
27Technical DataPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 % RHAccuracy (including non-linearity, hysteresis, and repeatability)with Vais
28115 (4.53)164 (6.46)125 (4.92)39 (1.5)73 (2.9)11 (0.43) 62 (2.4)Classification with Current OutputsEUROPE / VTTEU (94/9/EC, ATEX100a) II 1 G
29Ref. B210956EN-B ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners.
www.vaisala.com30HMT310 Humidity and Temperature Transmitter Reliable Vaisala HUMICAP® TechnologyThe HMT310 incorporates the latest-generation Vaisala
31Technical DataΔ °C°C-0.70.70.60.50.40.30.20.1-0.1-0.2-0.3-0.4-0.5-0.600-60 -40 -20 20 40 60 80 100120140160180-80Electrical ConnectionsTwo analog ou
32www.vaisala.comDimensional Drawings of the HMT310 Humidity and Temperature TransmitterTransmitter body dimensions in mm (inches)Probe dimensions in
6How to Choose the Right Instrument for Measuring Humidity and Dew PointPartial Pressure of Water VaporHumidity is simply water in its gaseous phase,
33Calculate and Convert.www.vaisala.com/humiditycalculatorAvailable also as: The free web based Vaisala Humidity Calculator allows you to calculate s
www.vaisala.com34Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 The Vaisala HUMICAP® Humidity and Temperature Transmitters H
35Technical DataHumidityPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracy including non-linearity, hysteresis, and repeatabilitytemp
36145721201164639M4; 4 pcs919278Wall Assembly dimensions Remote probe dimensionsø12 [0,47]71 [2,8]Ref. B21 1086EN-E ©Vaisala 2013This material is subj
37
www.vaisala.com38HMW90 Series Humidity and Temperature Transmitters for High Performance HVAC Applications Wall-mounted Vaisala HMW90 Series HUMICAP®
39Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityRef. B211183EN-D ©Vaisala 20
www.vaisala.com40HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC ApplicationsMeasures both Humidity and TemperatureThe HMD60 and HMD7
41Technical DataRef. B210839EN-B ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi
www.vaisala.com42HMDW110 Series Humidity and Temperature Transmitters for High-Accuracy Measurements in HVAC ApplicationsHMDW110 Series Humidity and T
7If saturation vapor pressure is reached in air or in a gas mixture, the introduction of additional water vapor requires that an equal amount condense
43HMW110/112 RH+T transmitters for measurements in wet areasHMD110/112 RH+T transmitters for ductsHMS110/112 RH+T transmitters for outdoor measurement
44ModelsModel number Type Output Special Features Ingress ProtectionHMW110 Wall-mount, RH+T 2-wire, current output Configurable model* IP65 HMW112 Wal
45Find out more at www.vaisala.com/HVAC
www.vaisala.com46HMS110 Series Humidity and Temperature Transmitters for High-Accuracy Outdoor Measurements in Building Automation ApplicationsVaisala
47Technical DataPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracyTemperature range +10 ... +30 °C (+50 ... +86 °F)0 ... 90 %RH ±2 %R
www.vaisala.com48HMDW80 Series Humidity and Temperature Transmitters for Building Automation Applications HMDW80 Series Humidity and Temperature Tran
49HumidityHMW88/89(D) RH+T transmitters for measurements in wet areas 76.9123.7955.581127.360.359Ø4.4Ø4.42032.424HMW82/83 RH+T and TMW82/83 T-only
50Technical DataModelsModel number Type Output Special Features Ingress ProtectionTMW82 Wall-mount, T-only 2-wire, current output IP30TMW83 Wall-mount
51HumidityRef. B211253EN-B ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual p
www.vaisala.com52HMS80 Series Humidity and Temperature Transmitters for Outdoor Measurements in Building Automation ApplicationsVaisala INTERCAP® Humi
8Mixing RatioThe mixing ratio (x) is the ratio of water vapor mass to the mass of dry gas. It is dimensionless but often expressed in grams per kilogr
53HumidityTechnical DataPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracyTemperature range +10 ... +30 °C (+50 ... +86 °F)0 ... 90 %
www.vaisala.com54HMD42/53 Humidity and Temperature Transmitters for Ducts in Commercial HVACApplicationsFeatures/Benefits▪Designed for building autom
55Technical DataRelative HumidityMeasurement range 0 ... 100 %RHTypical accuracyTemperature range 0 ... +40 °C (+32 ... +104 °F)0 ... 90 %RH ±3 %RH90
www.vaisala.com56HMM100 Humidity Module for Environmental Chambers The Vaisala HUMICAP® Humidity Module HMM100 is an open frame module for integration
57Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityMechanicsService cable conne
www.vaisala.com58Vaisala INTERCAP® Humidity and Temperature Probe HMP60HMP60The HMP60 is a simple, durable and cost-effective humidity probe. It is su
59Technical Data PerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHTypical accuracy temperature range 0 ... +40 °C0 ... 90 %RH ±3 %RH90 ...
www.vaisala.com60Vaisala HUMICAP® Humidity and Temperature Probe HMP110The HMP110 is a trouble-free and cost-effective humidity transmitter with high
61Technical Data Please contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityPerformanceRELATIVE HUMIDIT
www.vaisala.com62HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking ApplicationsThe Vaisala HUMICAP® Hand-Held Humidity and Temperature M
960°C the transmitter electronics should be mounted outside the process and only a suitable high temperature probe should be inserted into the high te
63Technical Data °C°C00-80 -60 -40 -20 20 40 60 80 100 120 140 160180-0.7-0.6-0.5-0.4-0.3-0.2-0.10.10.20.30.40.50.60.7HMP75, HMP76 and HMP77 ProbesMea
www.vaisala.com64Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM40 The HM40 is a compact and portable humidity meter at hand everywhere y
65Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationPerformanceRELATIVE HUMIDITYMeasurem
www.vaisala.com66HMI41 Indicator and HMP42/HMP46 ProbesThe Vaisala HUMICAP® Humidity Indicator HMI41 fitted with the Vaisala HUMICAP® Humidity and Tem
67Technical DataHMI41 IndicatorCalculated variables dew point temperature, absolute humidity,wet bulb temperature, mixing ratioResolution 0.1 %RH; 0.
68Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationAccessoriesTransmitter calibration c
69Get the latest news about technology, application solutions, instrumentation, and measurement practices.» Subscribe at www.vaisala.com/knowledgeIndu
www.vaisala.com70SHM40 Structural Humidity Measurement Kit SHM40 Structural Humidity Measurement Kit Vaisala HUMICAP® Structural Humidity Measurement
71Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityTemperatureMeasurement range
www.vaisala.com72HMK15 Humidity CalibratorNo measuring instrument stays accurate by itself. It is essential that the functioning of an instrument is p
10In a pressurized system a sample pump isn’t needed as the process pressure induces a large enough flow to the sampling cell.When measuring dew point
73Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityGeneralThe standard HMK15 co
www.vaisala.com74HMP155 Humidity and Temperature ProbeHMP155 with an additional temperature probe and optional Stevenson screen installation kit. Fea
75Technical DataRef. B210752EN-E ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi
www.vaisala.com76DTR500 Solar Radiation and Precipitation ShieldsThe Vaisala Solar Radiation Shield Series DTR500 are available in either a 5-, 9- or
77Technical DataRef. B210906EN-D ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi
www.vaisala.com78HMT330MIK Meteorological Installation Kit10095908580751234 56 7warmed proberegular probe The Vaisala Meteorological Installation Kit
79Technical DataRef. B210944EN-D ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi
www.vaisala.com80HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air MeasurementThe Vaisala HUMICAP® Turbine Mounting Kit HMT300TMK is develop
11Humidity sensors from Vaisala.The Right Humidity Instrument for the JobNo matter what the application, the total range of gas temperatures and expec
12Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 is a flexible product family designed for demanding industrial applications.clea
Comentarios a estos manuales