Chapter 2 ___________________________________________________________ Product Overview
VAISALA ________________________________________________________________________ 25
0604-060
Figure 2 Inside the Transmitter
The following numbers refer to Figure 2 above:
1
=
Service port (RS-232)
2
=
DIP switches for analog output settings
3
=
Power supply and signal wiring screw terminals
4
=
Relay, RS-422/485, data logger, LAN, WLAN, or analog
output module (optional)
5
=
Grounding connector for power supply module
6
=
Adjustment buttons (chemical purge buttons) with indicator
LED
7
=
Galvanic isolation module (optional)
8
=
Temperature probe cable
9
=
Humidity probe cable
10
=
BARO-1 module
11
=
Pressure port
12
=
Power supply module.