Default Settings of RS-232, RS-422, and
RS-485 for Europe
Operation Mode: NMEA Extended
Wind Speed Units: Meters/Second
Average Interval (seconds): 3
Averaging Method: Scalar
Output Interval (seconds, 0 for polled): 1
Sensor ID Character: A
Wind Direction Coast Threshold (speed units): 0.0*
Head Orientation: Up
Baud Rate: 9600b
Parity: None
Data Bits: 8
* 0.2 in sensors that are delivered to airport applications
NOTE
These default settings are delivered with product ordering options x2xxx
(for example, WS425 A2A1A, where the number 2 refers to the default
settings.)