Figure 28 Optical Signal Amplitude Distribution (in Rain)
DRD12 Signal Processing
The DRD12 output voltage is measured once a second by the DRI21
interface board. With dry surfaces, the voltage is approximately 3 V
and drops when the sensing elements become wet (Figure 29 below).
0110-186
Figure 29 DRD12 Surface Signal (Heavy Rain Beginning)