Vaisala Hydromet Data Collection Platform Manual de usuario Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 384
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
User's Guide ______________________________________________________________________
118 _________________________________________________________________ M210933EN-C
The sensor commands for interface configuration are as follows:
Message availability by sensor type is as follows:
The available data with FD Present Weather Sensor is as follows:
Operation Command(s) Description
Set polled AMES 2 0 or
AMES 7 0
Disables automatic transmission
Set automatic tx AMES 2 30 or
AMES 7 30
Enables automatic transmission of
message 2 or message 7 (PWD21/
PWD22/FD12P only) with 30-second
interval
Set device id CONF Activates configuration dialog
Sensor Messages
PWD11 2
PWD21 2,7
PWD22 2,7
FD12P 2,7
Lizard variable Message Description
pwd_id 2,7 Header text
dev_id 2,7 Device ID
alarms 2,7 Device alarm code
vis_1 2,7 Visibility 1 min average
vis_10 2,7 Visibility 10 min average
pw_nws 2,7 Present weather NWS code
pw_inst 2,7 Instant present weather code
pw_15 2,7 15 min present weather code
pw_1h 2,7 One hour present weather code
water_1h 2,7 Precipitation intensity mm/hour
water_cum 2,7 Cumulative water sum
snow_cum 2,7 Cumulative snow sum
t_xarm 7 Crossarm temperature
lumin 7 Background luminance
metar_i 7 Instant METAR weather code
metar_r 7 Recent METAR weather code
pw_insttxt 2,7 WMO text for instant present weather
code
pw_15txt 2,7 WMO text for 15 min present weather
code
pw_1htxt 2,7 WMO text for one hour present weather
code
Vista de pagina 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 383 384

Comentarios a estos manuales