User’s Guide ______________________________________________________________________
28 ___________________________________________________________________M210925EN-B
Selecting the Location
Finding a suitable site for WMT52 is important for getting
representative ambient measurements. The site should represent the
general area of interest.
The WMT52 should be installed in a location that is free from
turbulence caused by nearby objects, such as trees and buildings. In
general, any object of height (h) will not remarkably disturb wind
measurement at a minimum distance of 10 h. There should be at least
150 m open area in all directions from the mast. Refer to Figure 9 on
page 28.
0806-004
Figure 9 Recommended Mast Location in an Open Area