Vaisala HUMICAP HMT330 SERIES Guía de usuario Pagina 187

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 186
Appendix A _________________________________ Probe Installation Kits and Installation Examples
VAISALA ______________________________________________________________________ 185
T- Probe Installations (HMT337)
0508-015
Figure 98 Vapor Tight Installation
Vapor Tight Installation is not available from Vaisala.
The following numbers refer to Figure 98:
1 = Cable gland. For example AGRO 1100.12.91.065
(T= -25 ... +200 ºC)
2 = In pressurized processes, use a locking ring
(example: 6x 0.7 DIN471)
0508-022
Figure 99 Wall Mounting Installation
Wall Mounting Installation is not available from Vaisala.
The following numbers refer to Figure 99:
1 =
Cable gland. For example AGRO 1100.12.91.065
2 = Compacted PTFE sleeve
3 = Silicon glue between the PTFE sleeve and the cable
4 = Temperature probe
5 = Recommended support to keep the probe in horizontal
position
Vista de pagina 186
1 2 ... 182 183 184 185 186 187 188 189 190 191 192 ... 205 206

Comentarios a estos manuales

Sin comentarios