186 187
DMT344 Dewpoint and Temperature Transmitter
For Pressurized Processes
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Vaisala DRYCAP® Dewpoint and Temperature Transmitter DMT340 4 0 1 A 0 PRICE
1
Transmitter type DMT344 4 $2,960
2
Probe Cable lengths 2 m cable (6.6 ft) H
5 m cable (16.4 ft) J
$160
10 m cable (32.8 ft) K
$370
3
-
-
0
4
Measurement Dewpoint + PPM + Mixing ratio (for temperatures below 0° C) A
Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature (for temperatures above 0° C) B
5
Display No display 0
Graphic Display with Keypad 1 $320
6
Power Supply 10...35 VDC, 24 VAC
(HMT300PWS)
A
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
(DCDC-1) B $80
Universal AC -power (100....240 VAC)
(Power-1) C $200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991) D $210
External US AC-adapter (for LAN/WLAN interface in USA)
Not IP65 K $60
7
Analog Output Signal 4... 20 mA 1
for Ch1&Ch2(&Ch3) 0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
Analog Output Scaling No 3rd analog output A
for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) B B
B
Dewpoint (-60...+20 °C) ( -76...+68 °F) C C
C
Dewpoint (-50...+50 °C) ( -58...+122 °F) D D
D
Temperautre (0...+80 °C
(+32...+176 °F) E E
E
PPMv (0...1000 ppm) only for channel 1 G
PPMw (0...1000 ppm) only for channel 1 H
Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) J J
J
Relative humidity (0...100%) KK
K
SPECIAL Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) X X
X
Define scale for Ch1:_____________ Ch2:_____________ Optional Ch3:______________
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11
Operating Pressure 1 bar (abs) (14.5 psi abs) 1
3 bar (43.5) 2
5 bar (72.5) 3
7 bar (101.5) 4
9 bar (130.5) 5
special ( max 50 bar / 725 psi )** (bar / psi)(abs) X
12
Output Units Metric units A
Non-metric units B
13
Additional Option No Additional Option 0
Alarm Relay Output (Relay-1) 1 $180
RS-485 Serial Interface with Galvanic Isolation
(RS485-1)
2$160
LAN (Ethernet) interface + 2 m cable (RJ45) 4$260
WLAN (wireless Ethernet) interface + antenna 5$320
Data Logging Module
6$350
14
2nd Additional Option No Additional Option 0
Alarm Relay Output (Relay-1) 1 $180
3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 $160
Data Logging Module Not possible in the data logger has already been chosen in item 11
6 $350
15
User Cable Connection Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable)
(214728SP)
1
Conduit fitting for wire conduit (NPT1/2")
(214780SP) 2
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
3 $60
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
4$60
16
Transmitter Housing Wall Mounting A
Installation
Wall Mounting (for adapting to DMP248) (214829) B $90
Pipe/Pole Installation (215108) C $100
Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) D $110
DIN-Rail Installation
(215094) E $90
17
Dewpoint Sensor DRYCAP® 180M 1
18
Sensor Protection Sintered stainless steel filter
(HM47280SP)
A
Stainless steel filter for vacuum
(HM47453SP)
B
19
Probe Installation FITTING BODY M22 x 1.5
(17223)
2
Accessories FITTING BODY NPT1/2"
(17225) 3
20
User's guide language No manual A
English B
21
PC Accessories No PC Accessories 0
MI70LINK software for Windows® with RS232 service cable (215005) 2
$60
MI70LINK software for Windows® with USB service cable (219916) 4
$90
22
Calibration Standard Calibration, with NIST traceable certificate A
23
For future use 0
Selections in bold are included in the prices of the basic versions. TOTAL
Selections in italic are available at an extra price. QTY
Shaded sections indicate typical selections. TOTAL VALUE
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
Example of order code with typical settings:
DMT3404H0B1A1BEA1B001A1A3B0A0
DMT347 Dewpoint and Temperature Transmitter
With Small Pressure-tight Probe
1234567891011121314151617181920212223
aisala DRYCAP® Dewpoint and Temperature Transmitter
DMT340 7 0 1 A 0
PRICE
1
Transmitter type
DMT340
7
$2,460
2
Probe Cable lengths 2 m cable (6.6 ft)
S
5 m cable (16.4 ft) T $160
10 m cable (32.8 ft) U $370
3
-
- 0
4
Measurement Dewpoint + PPM + Mixing ratio (for temperatures below 0° C) A
Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature (for temperatures above 0° C) B
5
Display No display 0
Graphic Display with Keypad
1 $320
6
Power Supply
10...35 VDC, 24 VAC
(HMT300PWS) A
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
(DCDC-1) B $80
Universal AC -power (100....240 VAC)
(Power-1) C $200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991) D $210
External US AC-adapter (for LAN/WLAN interface in USA)
Not IP65 K $60
7
Analog Output Signal 4... 20 mA 1
for Ch1&Ch2(&Ch3) 0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
Analog Output Scaling No 3rd analog output A
for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) B B B
Dewpoint (-60...+20 °C) ( -76...+68 °F) C C C
Dewpoint (-50...+50 °C) ( -58...+122 °F) D D D
Temperautre (0...+80 °C)
(+32...+176 °F) E E E
PPMv (0...1000 ppm) only for channel 1 G
PPMw (0...1000 ppm) only for channel 1 H
Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) J J J
Relative humidity (0...100%) KKK
SPECIAL Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) X X X
Define scale for Ch1:_____________ Ch2:_____________ Optional Ch3:______________
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11
Operating Pressure 1 bar (abs) (14.5 psi abs) 1
3 bar (43.5) 2
5 bar (72.5) 3
7 bar (101.5) 4
9 bar (130.5) 5
special ( max 50 bar / 725 psi )** (bar / psi)(abs)
X
12
Output Units Metric units A
Non-metric units B
13
Additional Option No Additional Option 0
Alarm Relay Output
(Relay-1) 1 $180
RS-485 Serial Interface with Galvanic Isolation (RS485-1)
2 $160
LAN (Ethernet) interface + 2 m cable (RJ45)
4 $260
WLAN (wireless Ethernet) interface + antenna
5 $320
Data Logger Module
6 $350
14
2nd Additional Option No Additional Option 0
Alarm Relay Output
(Relay-1) 1 $180
3rd Analog output Choose also analog output signal for Ch3
(AOUT-1) 3 $160
Data Logger Module Not possible if the data logger module has already been chosen in item 11
6 $350
15
User Cable Connection Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) 1
Conduit fitting for wire conduit (NPT1/2") (214780SP) 2
Connector (M12, 8 pin) and Plug with 5m Black Cable (212142)
3$60
Connector (M12, 8 pin) and Plug for User's Cable (212416)
4$60
16
Transmitter Housing Wall Mounting A
Installation
Wall Mounting (for adapting to DMP248)
(214829) B $90
Pipe/Pole Installation
(215108) C $100
Pipe/Pole Installation with Rain Shield for Outdoor Installations
(215109) D $110
DIN-Rail Installation
(215094) E $90
17
Dewpoint Sensor DRYCAP® 180M 1
18
Sensor Protection Sintered stainless steel filter (HM47280SP) A
Stainless steel filter for vacuum (HM47453SP) B
19
Probe Installation Swagelok connector ISO 3/8" (SWG12ISO38) 4
Accessories Swagelok connector NPT 1/2" (SWG12NPT12) 5
Swagelok connector ISO 1/2"
SWG12ISO12 K
20
User's guide language No manual
A
English
B
21
PC Accessories
No PC Accessories
0
MI70LINK software for Windows® with RS232 service cable
(215005) 2
$60
MI70LINK software for Windows® with USB service cable
(219916) 4
$90
22
Calibration Standard Calibration, with NIST traceable certificate A
23
For future use 0
Selections in bold are included in the prices of the basic versions. TOTAL
Selections in italic are available at an extra price.
QTY
Shaded sections indicate typical selections. TOTAL VALUE
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
Example of order code with typical settings:
DMT3407S0B1A1BEA1B001A1A5B0A0