www.vaisala.com
142 143
Vaisala Weather Transmitter WXT520
Access to Real Time Weather Data
The WXT520 has an automatic control circuit that switches the heating on
at low temperatures.
Features/Benefits
Measures 6 most
essentialweather parameters
Accurate and stable
Low power consumption
– works also with solar panels
Compact, light-weight
Easy to install with one-bolt
mounting method
No moving parts
Heating available
Vaisala Configuration Tool
for pc
USB connection
IP66 housing with mounting kit
Applications: weather stations,
dense networks, harbors,
marinas
Measuring acoustic
precipitation
The WXT520 precipitation
measurement is based on the unique
Vaisala RAINCAP
®
Sensor, which
detects the impact of individual
rain drops. The signals exerting
from the impacts are proportional
to the volume of the drops.
Hence, the signal from each drop
can be converted directly to the
accumulated rainfall.
The WXT520 measures accumulated
rainfall, rain intensity and duration of
the rain — all in real time.
The Vaisala RAINCAP
®
Sensor is the
only maintenance-free precipitation
sensor on the market.
WXT520
The Vaisala Weather Transmitter
WXT520 measures barometric
pressure, humidity, precipitation,
temperature, and wind speed and
direction.
To measure wind speed and
direction, the WXT520 has the
Vaisala WINDCAP
®
sensor that uses
ultrasound to determine horizontal
wind speed and direction.
The array of three equally spaced
transducers on a horizontal plane is
a Vaisala specic design. Barometric
pressure, temperature, and humidity
measurements are combined in
the PTU module using capacitive
measurement for each parameter.
It is easy to change the module
without any contact with the
sensors.
The WXT520 is immune to ooding
clogging, wetting, and evaporation
losses in the rain measurement.
Technical data
Liquid precipitation
RAINFALL
cumulative accumulation after the
latest automatic or manual reset
output resolutions and
units 0.01 mm, 0.001 inches
accuracy 5%*
RAINFALL DURATION
counting each ten-second increment
whenever water droplet is detected
output resolution and
unit 10 s
RAIN INTENSITY
one-minute running average
in ten-second steps
range 0 ... 200 mm/h (broader range with
reduced accuracy)
output resolutions and
units 0.1 mm/h, 0.01 inches/h
HAIL
cumulative amount of hits against
the collecting surface
output resolutions and
units 0.1 hits/cm2, 0.01 hits/in2, 1 hits
HAIL DURATION
counting each ten-second increment
whenever hailstone is detected
output resolution and unit 10 s
HAIL INTENSITY
one-minute running average
in ten-second steps
output resolutions and
units
0.1 hits/cm2h, 1 hits/in2h,
1 hits/h
* Due to the nature of the phenomenon, deviations caused by
spatial variations may exist in precipitation readings, especially
in a short time scale. The accuracy specification does not include
possible wind induced errors.
Wind
SPEED
range 0 ... 60 m/s
response time 250 ms
accuracy
0 ... 35 m/s ±0.3 m/s or ±3%,
whichever is greater
35 m/s ... 60 m/s ±5%
output resolutions and 0.1 m/s, 0.1km/h,
units 0.1 mph, 0.1 knots
DIRECTION
azimuth 0 ... 360°
response time 250 ms
accuracy ±3°
output resolution and unit
Air temperature
Range -52 ... +60 °C (-60 ... +140 °F)
Accuracy for sensor at +20 °C ±0.3 °C (±0.5 °F)
Accuracy over temperature range (see graph below)
Barometric pressure
Range 600 ... 1100 hPa
Accuracy ±0.5 hPa at 0 ... +30 °C (+32 ... +86 °F)
±1 hPa at -52 ... +60 °C (-60 ... +140 °F)
Output resolutions and
units
0.1 hPa, 10 Pa, 0.0001 bar,
0.1 mmHg, 0.01 inHg
Relative humidity
Range 0 ... 100 %RH
Accuracy ±3 %RH within 0 ... 90 %RH
±5 %RH within 90 ... 100 %RH
Output resolution and unit 0.1 %RH
General
Operating temperature -52 ... +60 °C (-60 ... +140 °F)
Storage temperature -60 ... +70 °C (-76 ... +158 °F)
Operating voltage 5 ... 32 VDC
Typical power consumption 3 mA at 12 VDC (with defaults)
Heating voltage 5 ... 32 VDC / 5 ... 30 VAC
RMS
)
Serial data interface SDI-12, RS-232, RS-485, RS-422,
USB connection,
Weigth 650 g (1.43 lb)
Housing IP65
Housing with mounting kit IP66
Output resolutions and units 0.1 °C, 0.1 °F
Ref. B210417EN-F ©Vaisala 2010
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
Electromagnetic compatibility
Complies with EMC standard
EN61326-1; Industrial
Environment IEC standards
IEC 60945/61000-4-2 ... 61000-4-6
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Δ
&
&
















 




Wind
Vista de pagina 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 122 123

Comentarios a estos manuales

Sin comentarios