Chapter 5 _________________________________________________________________ Operation
Data Messages
Depending on the settings, there are two modes in WMT700 for
sending data messages to the serial ports:
- Poll mode
- Automatic message mode
The data messages can contain measurement data calculated by
WMT700 and information on the status and properties of the
wind sensor.
For the Automatic message mode, you need to set the following
parameters:
- autoInt (defines the message send interval in seconds, 0.25 s
resolution)
- autoSend (0 = Automatic message mode disabled, for available
messages, see Table 40 on page 128.
- autoPort (defines where the message is sent: 1 = COM1,
2 = COM2)
When the WMT700 protocol is used, you can use either one of
the predefined message formats or user-configurable data
message format.
Table 40 on page 128 lists the data messages supported by
WMT700. The data message numbers in the table below are
needed when the WMT700 protocol POLL command is used or
the Automatic Message mode is used with any protocol.
VAISALA _______________________________________________________________________ 127