User's Guide ______________________________________________________________________
Table 60 Outputs
COM1: RS-485
COM2: RS-485, RS-422, RS-232, SDI-12
WMT700, WS425 ASCII, NMEA Standard
and Extended (version 0183), SDI-12 (version
1.3), WS425 ASOS, ROSA - MES12,
300, 1200, 2400, 4800, 9600, 19200, 38400,
57600, or 115200
Frequency push-pull
Pulse 0 V/10 V: 0 ... 2 kHz (f = 10 Hz/m/s)
in
-2 V (11 V min.): 0 ... 750 Hz
(Load 50 kohm ±20%)
in
-4 V (8 V min.): 0 ... 750 Hz
(Load 50 kohm ±20%)
0 ... 10 V (U = 100 mV /m/s)
0 ... 20 mA (I = 0.2 mA/m/s)
Voltage
Current
0 ... 20 mA (I = 50 uA//°)
Reference voltage 1 ... 10 VDC
0 ... V
ref
represents 0 ... 359°
m/s, knots, mph, km/h, V, mA, Hz
Automatic Message or Poll Mode
NOTE
In extreme weather conditions, ice or snow accumulation may cause a
temporary wind measurement blackout even when the heating is enabled.
WMT700 indicates this with missing readings or in the data message.
190 __________________________________________________________________ M211095EN-E