Chapter 4 ________________________________________________________________ Installation
Heating Power
Table 27 below lists the minimum power supply requirements of
each WMT700 heating option.
NOTE
In maritime environments, the normal inpu
t voltage ranges are: operating
… 30 VDC (-10% … +30%) and heating voltage
… 30 VDC (-10% … +30%), as defined in the maritime standard
60945.
Table 27 Heating Power Supply Requirements
Required Heating
Power Supply
Transducers, arms and body
Power and Cable Recommendations for Fully
Heated WMT700
Table 28 below shows cable and power recommendations. If a
longer than a 10 meter cable is needed, it is recommended to use
Junction Box with Cable (WMT70CABLE12) for extending the
cable length.
NOTE
The minimum operation voltage for a fully heated WMT700
(transducers,
arms, and body heated) is 16 V, if a separate power supply
unit is used for operation.
Table 28 Heating Power and Extension Cable
WMT70CABLE2*
* Vaisala standard connection cable.
** Not for maritime use.