Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 43
Output Reading Once
Syntax in STOP mode: SEND<cr>
Syntax in POLL mode: SEND aa<cr>
Where
aa
=
Address of the transmitter when more than one transmitter is
connected to a serial bus (0 ... 99).
Set Serial Interface Mode
Syntax: SMODE x<cr>
Where
x
=
STOP/RUN/POLL
STOP
mode: Transmitter in standby for serial
commands
RUN
mode: Transmitter outputs data continuously
POLL
mode: Transmitter only responds to
addressed command
Example:
>smode run
Output mode : RUN
>smode stop
Output mode : STOP
Serial Line Settings
Syntax: SERI b p d s<cr>
Where
b
=
bauds (300, 600, 1200, 2400, 4800, 9600,19200)
p
=
parity (n = none, e = even, o = odd)
d
=
data bits (7 or 8)
s
=
stop bits (1 or 2)
The settings can be changed one parameter at a time or all parameters at
once.