Vaisala HUMICAP® Humidity and Temperature
Transmitters HMT120 and HMT130
The Vaisala HUMICAP
®
Humidity and
Temperature Transmitters HMT120
and HMT130 are designed for
humidity and temperature monitoring
in cleanrooms and are also suitable
for demanding HVAC and light
industrial applications.
Performance
The HMT120/130 incorporates Vaisala
HUMICAP
®
technology that measures
relative humidity accurately and
reliably. The Vaisala HUMICAP
®
is
resistant to dust and most chemicals.
The transmitter enclosure is
optimized for use in cleanrooms.
The smooth surface of the enclosure
makes it easy to clean and the
enclosure material is chosen
to tolerate purifying agents.
Furthermore, the cabling can be
done through the back wall of the
transmitter.
The HMT120/130 with and without a display.
Interchangeable Probe
The HMT120/130 transmitters use
a fully interchangeable relative
humidity probe. The probe can
be easily removed and replaced
with a new one without having to
adjust the transmitter, which allows
for easy and quick recalibration
of the transmitter. The probe can
be adjusted using one of Vaisala’s
portable meters as a reference.
Also available is a constant output
probe with fixed RH and T output
for convenient inspection of the
monitoring system and signal
transfer line.
Available Options
The HMT120 and HMT130
transmitters are available as wall
mounted or with remote probe. For
high temperature applications or
where space is limited, the remote
probe is ideal. The transmitters
come with an optional LCD display,
which shows the measurement
results of selected parameters in
selected units. The parameters are
displayed simultaneously at two
separate rows on the display.
Features/Benefits
Vaisala HUMICAP
®
technology
with humidity sensor
HUMICAP
®
180R
Humidity parameter options:
relative humidity, dew
point/frost point, wet bulb
temperature, enthalpy, absolute
humidity, mixing ratio, vapor
pressure, and saturation vapor
pressure
2-wire loop-powered or 3-wire
voltage output configurations
Interchangeable probe
(easy field calibration)
Accurate and reliable
Resistant to dust and most
chemicals
Optional LCD display
USB cable available for a PC
connection for maintenance
Wall-mounted or with a
remote probe
Constant output probe
available
Can be mounted outdoors
using a Vaisala installation
kit and the Vaisala Radiation
Shield DTR504A
Enclosure IP65
3-point NIST traceable
calibration (certificate
included)
Suitable for cleanrooms and
demanding HVAC and light
industrial applications