HMDW110 Series Humidity and Temperature
Transmitters for High-Accuracy Measurements
in HVAC Applications
HMDW110 Series Humidity and Temperature Transmitters for measurements in
ducts, outdoor environments, and humid areas.
Features/Benefits
▪
Accurate humidity and
temperature transmitters for
measurements in HVAC and
cleanroom applications
▪
Outdoor transmitter with
professional-grade radiation
shield
▪
Proven HUMICAP® 180R sensor
for superior long-term stability
▪
±2 %RH accuracy
▪
3-point NIST traceable
calibration (certificate
included)
▪
On-site calibration with
HM70 Hand-Held Meter or PC
connection
▪
Current output (4 … 20 mA)
▪
Default output parameters
are relative humidity and
temperature. Dew point
temperature, wet bulb
temperature, and enthalpy
outputs selectable with a
PC connection.
Vaisala HUMICAP
®
Humidity and
Temperature Transmitter Series
HMDW110 measure relative humidity
and temperature in multiple HVAC
applications. The series includes
transmitters for duct mounting,
IP65-classified wall transmitters, and
outdoor transmitters with integrated
radiation shields.
Proven Vaisala HUMICAP®
Performance
The cost-efficient HMDW110 series
transmitters are equipped with trusted
HUMICAP
®
180R sensors. The sensor’s
superior long-term stability minimizes
maintenance needs throughout the
transmitter’s lifetime. If necessary,
the transmitter can be field-calibrated
using either an HM70 Hand-Held
Humidity and Temperature Meter, or a
PC connection.
HMDW110 series instruments are
individually adjusted and delivered
with a calibration certificate. The
factory calibration is traceable to
NIST.
Unrivaled Outdoor
Humidity Measurements
The integrated radiation shield of the
outdoor models HMS110 and HMS112
enables unrivaled measurement
performance. It reduces the impact
of sunshine on temperature and
humidity measurements, and ensures
measurement accuracy in outdoor
conditions. The most popular
control parameters in free cooling
– dew point temperature, wet bulb
temperature, and enthalpy – are
available as output parameters.
Well-Suited for
Cleanroom Monitoring
The HMD110 and HMW110
transmitters can be ordered with
a catalytic HUMICAP
®
sensor
HUMICAP
®
180VHP. The catalytic
sensor improves stability especially
in hydrogen peroxide sterilized
environments where repeated
condensation is expected.
An optional panel display can
be added for remote monitoring.
Transmitters can be installed into
difficult-to-reach locations, while
measurement data can be read from
a more convenient spot.