User's Guide ______________________________________________________________________
168 __________________________________________________________________M210630EN-B
Weather Transmitter
Cleaning
To ensure the accuracy of measurement results, Weather Transmitter
WXT510 should be cleaned when it gets contaminated. Leaves and
other such particles should be removed from the precipitation sensor
and the transmitter should be cleaned carefully with a soft, lint-free
cloth moistened with mild detergent.
Replacing the PTU Module
1. Turn the power off.
2. Loosen the three screws at the bottom of WXT510.
3. Pull out the top of the transmitter.
4. Release the small white flap and remove the PTU module.
5. Connect a new PTU module (order code WXT510PTUSP), replace
the top and tighten the three bottom screws.
6. Turn the power on.
CAUTION
Be extremely careful when cleaning the wind sensors. The sensors
should not be rubbed nor twisted.