User's Guide ______________________________________________________________________
62 ___________________________________________________________________M210630EN-B
c. Connect the wires from the battery to the Power connector
(number 1 in Figure 42 on page 61): the black wire to the
GND connector and the red wire to the Batt connector.
d. After the installation is finalized, open the MAWS Terminal
software. In the Tools menu, select Station Settings to change
the capacity of the internal battery from 1.2 to 2.4 Ah.
6. To keep the tube watertight, the tube should cover the two O-rings
(number 1 and 2 in Figure 43 on page 62) on the bottom of the
upper base. Rotate the tube to find the aligning pins (number 2 in
Figure 44 on page 62) position. Slide the tube up. Tighten it with
the hand screw (number 1 in Figure 44 on page 62).
0404-029
Figure 43 O-rings for Sealing the Tube
0201-021
Figure 44 Hand Screw and Aligning Pins
CAUTION
Make sure that the pressure vent tube does not get blocked or bent